Let China-tec, Serve People More

HOME                COMPANY                PRODUCT                SERVICE                NEWS                OEM                CONTACT US
¡¤ CMEF Shenzhen April 2012
¡¤ CMEF Spring, Shenzhen, Ap
¡¤ CMEF Regional, Chengdu, S
¡¤ CMEF Spring, Shenzhen, Ap
 Health Care
Product Name: Fingertip Pulse Oximeter LED display
Model: TPO-50dl1
P/N:
Inquiry:



 

Instructions

Principle of the CMS50DL1 Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance

with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and

pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in

sports(It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport)

and etc.


Major Features

¡öIntegrated with SpO2 probe and processing display module
¡öSmall in volume¡¢light in weight and convenient in carrying
¡öOperation of the product is simple ,low power consumption
¡öSpO
2 value display
¡öPulse rate value display, bar graph display
¡öLow-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
¡öAutomatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5

seconds if the finger falls out of probe.

Main performance

¡ö Display Mode: LED display
¡ö SpO2 Measuring Range: 0%¡«100%, (the resolution is 1%).
¡ö Accuracy: 70%¡«100%: ¡À2% ,Below 70% unspecified.
¡ö PR Measuring Range: 30bpm¡«250bpm, (the resolution is 1bpm)
¡ö Accuracy: ¡À2bpm or ¡À2% (select larger)
¡ö Measurement Performance in Weak Filling Condition:
¡ö SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ¡À4%,

pulse rate error is ¡À2 bpm or ¡À2% (select larger).
¡ö Resistance to surrounding light: The deviation between the value measured in the condition of man-made light

or indoor natural light and that of darkroom

¡ö is less than ¡À1%.
¡ö Power Consumption: less than 25 mA
¡ö Voltage: DC 3.0V
¡ö Power Supply: 1.5V (AAA size) alkaline batteries ¡Á 2
¡ö Battery working hour: The minimum continually work time is 24 hours, theoretical number is 56 hours.
¡ö Safety Type: Interior Battery, BF Type

Accessories

Sell in standard:
¡öA hanging rope
¡öA user manual

Physical Identity
Dimension: 61(L) ¡Á 36(W) ¡Á 32(H) mm
Weight: About 50g (with the batteries)

2008-2012 Topcn Medical Co., Ltd. All rights reserved.